AKS33060G2104,Danfoss壓力傳感器
AKS 壓力傳感器設計用于精確和優(yōu)化能量的控制。
完備的設計使得 AKS適用于各種應用,例如:
-空調系統(tǒng)
-制冷設備
-工藝過程控制應用
-實驗室應用
產(chǎn)品系列
4 - 20 mA (AKS 33, AKS 3000)
1 - 5 V DC, 1 - 6 V DC, 0 - 10 V DC (AKS 32)
10 - 90% 比例輸出 (AKS 32R)
AKS 33是壓力傳感器,將測量所得的壓力轉換成一個4-20mA 電流輸出信號。輸出信號可以適用于ADAP-KOOL®制冷控制系統(tǒng)。
特性
|
價值
|
| 類型 |
AKS 33 |
| 質量[kg] |
0.210 [kg] |
| - common |
Pin 2 |
| + supply |
Pin 1 |
| Accuracy, max. ±FS [%] |
0,80 % |
| Accuracy, typical ±FS [%] |
0,3 % |
| Adjustment, zero point and span |
沒有 |
| Ambient temperature range [°C] |
-40 - 85 °C |
| Ambient temperature range [°F] |
-40 - 185 °F |
| 認證 |
ATEX, C UR, CSA, GOST POCC |
| Approval note |
ATEX Ex nA IIA T3 Gc |
| Approval standard |
6967179 |
| Approval standard |
E227388 |
| Approval standard |
E31024 |
| Compensated temperature range [°C] |
-30 - 40 °C |
| Compensated temperature range [°F] |
-22 - 104 °F |
| EAN number |
5702422066026 |
| Electrical connection type |
Pg 9, EN 175301-803-A, Male and Female |
| Enclosure rating |
IP65 |
| Flush diaphragm |
沒有 |
| Intrinsically safe |
沒有 |
| Medium temperature range [°C] |
-40 - 85 °C |
| Medium temperature range [°F] |
-40 - 185 °F |
| Non-linearity Best Fit Straight Line ±FS [%] |
0,20 % |
| Output signal type |
4 - 20 mA |
| Max. overload pressure [bar] |
33,0 bar |
| Max. overload pressure [psi] |
479 psi |
| 包裝形式 |
Multi pack |
| Pressure connection standard |
EN 837 |
| Pressure connection type |
G - 3/8 Male |
| 壓力范圍[bar] |
-1,00 - 6,00 bar |
| Pressure range [psi] |
-14,50 - 87,00 psi |
| Pressure unit reference |
Gauge (relative) |
| Pulse snubber |
沒有 |
| 每標準包裝的數(shù)量 |
14 pc |
| Max. response time [ms] |
4 ms |
| Specification key |
AKS 33 |
| Supply voltage [V] DC |
10,00 - 30,00 V |